Molded & Insulated Case Circuit Breakers

While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

QPHW3070H Cutler-Hammer Circuit Breaker

Cutler-Hammer QPHW3070H circuit breaker; 70 amp, 240 volt, three pole, used electrically OK.
SKU: QPHW3070H
Contact us for pricing:

QPHW3080H Cutler-Hammer Circuit Breaker

Cutler-Hammer QPHW3080H circuit breaker; 80 amp, 240 volt, three pole, used electrically OK.
SKU: QPHW3080H
Contact us for pricing:

QPHW3090H Cutler-Hammer Circuit Breaker

Cutler-Hammer QPHW3090H circuit breaker; 90 amp, 240 volt, three pole, used electrically OK.
SKU: QPHW3090H
Contact us for pricing:

QPHW3100H Cutler-Hammer Circuit Breaker

Cutler-Hammer QPHW3100H circuit breaker; 100 amp, 240 volt, three pole, used electrically OK.
SKU: QPHW3100H
Contact us for pricing:

RD316T35W Cutler-Hammer Breaker RD 65K 1600 Amp 600 VAC MO/FM

Cutler-Hammer RD316T35W Breaker Type RD 65K; 1600 amp, 600 VAC, 3 pole. Digitrip RMS310 cat# RES1600LSG with 1600 amp rating plug cat# 16RES16T, auxiliary switch cat# A2X6RPK. Manually operated, fixed-mount. Used tested with report.
SKU: MCCB1829
$7,500.00

RD316T36W Cutler-Hammer Breaker RD 65K 1600 Amp 600 VAC LSIG M/O F/M

Cutler-Hammer RD316T36W Breaker RD 65K; 1600 amp, 3 pole, 600 volt AC. Digitrip RMS310 cat# RES1600LSIG with LSIG functions, ground fault, 1600 amp rating plug cat # 16RES16T, manually operated (M/O), fixed-mount (F/M). Used tested with report.
SKU: MCCB1968
$7,500.00

RD320TW Westinghouse "C" Series Breaker 2000 Amp 600 VAC M/O

Westinghouse "C" Series RD320TW circuit breaker; 2000 amp, 600 volt AC, 3 pole. With 2000 amp rating plug cat.#20RS20T, RS Seltronic trip cat.#RS32000T, manually operated (M/O), used tested with report.
SKU: MCCB1193
$4,200.00

RDC320T33W Cutler-Hammer Breaker RDC 100k 2000 Amp 600 VAC M/O F/M

Cutler-Hammer RDC320T33W Circuit Breaker; RDC 100k, 2000 amp, 600 volt AC, three pole. With Digitrip RMS 310, 2000 amp rating plug cat # 20RES20T, manually operated (M/O), fixed-mount (F/M). Used tested with report.
SKU: MCCB1871
Contact us for pricing:

S8V-D ABB Molded Case Switch 2500 Amp 600 Volt MO/FM

ABB S8V-D Molded Case Switch; 2500 amp, 600 volt, three pole. With closing coil, shunt trip removed, auxiliary switch, motor, manually operated (M/O), fixed-mount (F/M), used tested with report.
SKU: MCCB1853
Contact us for pricing:

SACE E2 ABB Breaker 1600 Amp 600 VAC M/O D/O

ABB SACE E2 breaker; SACE E2N-A 16, 1600 amp, 600 volt AC, 3 pole. With SACE PR113/P-A trip unit, manually operated (M/O), draw-out (D/O) with mounting cell, used tested with report.
SKU: MCCB1589
$3,300.00

SACE E2 ABB Breaker 1600 Amp 600 VAC M/O D/O

ABB SACE E2 breaker; SACE E2N-A 16, 1600 amp, 600 volt AC, 3 pole. With SACE PR113/P-A  trip unit, manually operated (M/O), draw-out (D/O) with mounting cell, used tested with report.
SKU: MCCB1590
$3,300.00

SACE E2N-A16 ABB Breaker 1600 Amp 600 VAC M/O D/O

ABB SACE E2N-A 16 breaker; 1600 amp, 600 volt AC, 3 pole. With SACE PR113/P-A trip unit, manually operated (M/O), draw-out (D/O), used tested with report.  *(Missing Trip Cover)*
SKU: MCCB1427
$3,300.00

SACE E2N-A16 ABB Breaker 1600 Amp 600 VAC M/O D/O

ABB SACE E2N-A 16 circuit breaker; 1600 amp, 600 volt AC, 3 pole. With SACE PR113/P-A trip unit, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1428
$3,300.00

SACE E2N-A16 ABB Breaker 1600 Amp 600 VAC M/O D/O

ABB SACE E2N-A 16 circuit breaker; 1600 amp, 600 volt AC, 3 pole. With SACE PR113/P-A trip unit, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1430
$3,300.00

SACE E2N-A16 ABB Breaker 1600 Amp 600 VAC M/O D/O

ABB SACE E2N-A 16 circuit breaker; 1600 amp, 600 volt AC, 3 pole. With SACE PR113/P-A trip unit, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1431
$3,300.00

SBH 4000 Siemens SBH4040 Circuit Breaker 4000 Amp 600 VAC MO/FM

Siemens SBH 4000 breaker cat.# SBH4040, 4000 amp trip unit cat.# SB40TLSIG with LSIG functions, 4000 amp rating plug, 600 VAC, manually operated, fixed mount, used tested with report.
SKU: MCCB22309
$21,000.00

SBH1600 Siemens Breaker 1600 Amp 600 VAC E/O D/O

Siemens SBH1600 circuit breaker; cat.# SBH2016DV, 1600 amp, 600 volt AC, 3 pole. With 1200 amp rating plug cat.# 16SB1200, shunt trip #SBST24, auxiliary switches #SBAS8, bell alarm #SBBA120, electrical operator # SBEO120, draw-out carriage # SBH20DFV, electrically operated (E/O), draw-out (D/O), used tested with report.
SKU: MCCB1775
$5,100.00

SBS4000 Siemens Breaker 4000 Amp 600 VAC MO/STA

Siemens SBS 4000 breaker; cat.# SBS4040F, 4000 amp, 600 volt AC, 3 pole. With trip unit cat.# SB40TLSIG, LSIG functions, ground fault, 3000 amp rating plug, manually operated, stationary, used tested with report.
SKU: MCCB24538
$18,000.00

SBS5000 Siemens Breaker 5000 Amp 600 VAC W/ 4000 Amp Rating Plug E/O F/M

Siemens SBS5000 Breaker; 5000 amp, 600 VAC, with 4000 amp rating plug cat# 50SB4000, shunt trip cat# SB4ST120, auxiliary switch cat# SB4AS8EC, bell alarm cat# SBBA120, electric operator (E/O) cat# SB4EO120CCX, fixed-mount (F/M). Used tested with report.
SKU: MCCB1897
$30,000.00

SBS612 Eaton/ Cutler-Hammer Magnum SB 1200 Amp 600 VAC M/O D/O

Eaton/ Cutler-Hammer SBS612 Magnum SB; cat.# SBS6123WEA, 1200 amp, 600 volt AC, 3 pole. With Digitrip 520 trip unit cat.# 5LSIG, LSIG functions, ground fault, 1000 amp rating plug, auxiliary switches, manually operated (M/O), draw-out (D/O) with draw-out carriage, used tested with report.
SKU: MCCB1673
$5,700.00

New, Used, and Tested Molded & Insulated Case Circuit Breakers

EMSCO has been specializing in used and refurbished molded & insulated case circuit breakers for over 72 years.


Why Choose EMSCO for Molded Case or Insulated Case Circuit Breakers?

Want to match and replace your existing breakers? End the hassle of retrofitting your electrical system. Our extensive inventory includes a variety of Molded Case Circuit Breakers (MCCBs) and Insulated Case Circuit Breakers that are designed to seamlessly match and replace your existing breakers by brand, amp rating, voltage, frame size, or model.

 

New and Refurbished Products in Stock

We understand that budgets and preferences differ, so we give you the option of selecting between new and refurbished MCCBs or Insulated Case Breakers, both of which are readily available in our inventory. Choose brand-new circuit breakers for maximum performance and longevity, or look into our refurbished options, which have been rigorously tested and reconditioned to meet industry standards.

 

Popular Brands and Common Configurations

Our shelves are stocked with breakers from the most trusted and popular brands in the industry, ensuring you have access to dependable products. You'll find common configurations, such as different frame sizes and voltage ratings, making it simple to find the right circuit protection for your application.

 

Avoiding Costly Operational Downtime

Downtime can be an expensive situation. Our circuit protection products are designed for high performance and durability. You can avoid costly operational downtime due to electrical failures by using our fully-tested Molded Case or Insulated Case breakers. Our products provide reliable power and superior equipment protection.

 

Electrical Testing Equipment Certifying Quality and Performance

When it comes to the dependability and safety of your electrical systems, we leave nothing to chance. Our breakers are rigorously tested using current testing equipment to ensure that they meet or exceed industry standards. This ensures that your electrical installations are safe and efficient.

  • Overcurrent Protection: We verify that your breakers provide accurate overcurrent protection, guaranteeing the safety of your electrical systems.
  • Trip Time: We measure the time it takes for breakers to respond to overcurrent conditions, ensuring it operates within the specified trip time.
  • Short-Circuit Withstand Capacity: Our testing evaluates the breaker’s ability to withstand short-circuit currents, preventing damage and maintaining safety.
  • Interrupting Capacity: We determine the MCCB's capability to interrupt fault currents, ensuring the utmost protection for your electrical system.

 

Molded Case Circuit Breaker Specifications

A sample table of ampere ratings, corresponding voltage ratings, and frame sizes for molded case circuit breakers is shown below. Please keep in mind that frame sizes and ratings can differ between manufacturers and models. For precise details on a specific MCCB, always refer to the manufacturer's specifications.

 

Frame Size

Ampere Rating

Voltage Rating

A

15A

120V, 240V

A

20A

120V, 240V

B

30A

120V, 240V, 480V

B 50A 120V, 240V, 480V
C 60A 240V, 480V
C 100A 240V, 480V
D 150A 240V, 480V, 600V
D 200A 240V, 480V, 600V
E 250A 240V, 480V, 600V
E 300A 240V, 480V, 600V
F 400A 240V, 480V, 600V
F 600A 240V, 480V, 600V
G 800A 240V, 480V, 600V
G 1200A 240V, 480V, 600V
H 1600A 240V, 480V, 600V

 

This table is a sample representation of frame sizes, ampere ratings, and voltage ratings for Molded Case Circuit Breakers, not an exhaustive list.

 

Molded case circuit breakers (MCCBs) and insulated case circuit breakers (ICCBs) are two distinct types of circuit protection devices used in electrical systems. Both serve the purpose of interrupting electrical currents in case of faults or overloads, but they differ in construction, application, and performance characteristics. Need Help Now? Call 800-328-1842.