While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

Square D Masterpact NW20H1 Circuit Breaker 2000 Amp 600 VAC E/O D/O Tested

Square D NW20H1 Masterpact circuit breaker: cat# WA4FFR63A3CFBFXXCX, 2000 amp, 600 volt AC, three pole. With Micro logic 5.0 P trip unit, LSI functions, modbus, spring charging motor- 100-130 VAC, shunt trip- 24-30 VAC/DC, closing coil- 100-130 VAC/DC, electrically operated (E/O), draw-out (D/O), used tested with report.
SKU: MCCB1505
$7,500.00

Square D Masterpact NW20L1 Circuit Breaker 2000 Amp 600 VAC M/O D/O Tested

Square D NW20L1 Masterpact circuit breaker; cat #WA8FFR64A3DXBXXXCA, 2000 amp frame, 600 volt AC, 2000 amp rated. With Micrologic 6.0P trip unit with LSIG functions, ground fault, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1410
$7,500.00

Square D Masterpact NW20L1 Circuit Breaker 2000 Amp 600 VAC M/O D/O Tested

Square D NW20L1 Masterpact circuit breaker; cat# WA8FFR64A3DXBXXXCA, 2000 amp frame, 600 volt AC, 3 pole. With 2000 amp rated Micro logic 5.0P trip unit, LSI function, modbus, shunt trip- 24-30 Volt AC/DC, pad lockable, push button cover, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1411
$6,000.00

Square D MasterPact NW20N Circuit Breaker 2000 Amp 600 Volt AC E/O D/O

Square D MasterPact NW20N Circuit Breaker; cat# WL1FF33A9SXXXXXXX, 2000 Amp, 600 volt AC, 3 pole. With micrologic 5.0A trip unit, LSI functions, electrically operated (E/O), draw-out (D/O). Used tested with report.
SKU: MCCB2044
Contact us for pricing:

Square D MasterPact NW20N Circuit Breaker 2000 Amp 600 Volt AC E/O D/O

Square D MasterPact NW20N Circuit Breaker; cat# WL1FFR33A9SXXXXXXX, 2000 Amp, 600 volt AC, 3 pole. With micrologic 5.0A trip unit, LSI functions, electrically operated (E/O), draw-out (D/O). Used tested with report.
SKU: MCCB2045
Contact us for pricing:

Square D MasterPact NW30H Circuit Breaker 3000 Amp 600 Volt AC M/O F/M

Square D MasterPact NW30H Circuit Breaker; cat# WL3HGG43A9SXFXXXXX 3000 amp, 600 volt AC, 3 pole. With 2500 amp rating plug, manually operated (M/O), fixed-mount (F/M). Used tested with report. **No Trip Unit
SKU: MCCB2064
Contact us for pricing:

Square D MasterPact NW32H1 Circuit Breaker 3200 Amp 600 VAC M/O D/O

Square D NW32H1 MasterPact circuit breaker: 3200 amp, 600 volt AC, three pole. With MicroLogic 6.0A unit trip with LSIG functions, ground fault, manually operated (M/O), draw-out (D/O). Used tested with report.
SKU: MCCB1916
$12,500.00

Square D MasterPact NW32H1 Circuit Breaker 3200 Amp 600 Volt AC M/O R/O

Square D MasterPact NW32H1 Low-Voltage Power Circuit Breaker; cat# WA4JJR64A3CFFFXXCA, 3200 amp, 600 volt AC. With micrologic 6.0P trip unit, manually operated (M/O), roll-out (R/O). Used tested with report. *Missing 1/2 of 1 stab-on clips*
SKU: MCCB2023
Contact us for pricing:

Square D MasterPact NW32H2 Circuit Breaker 3200 Amp 600 Volt AC M/O D/O

Square D MasterPact NW32H2 Circuit Breaker; cat# WASJJR64A3GXXXWXCX, 3200 amp, 600 volt AC, 3 pole. With micrologic 6.0 P trip unit, manually operated (M/O), draw-out (D/O). Used tested with a report.
SKU: MCCB2109
Contact us for pricing:

Square D Masterpact NW40H2 Circuit Breaker 4000 Amp 600 VAC E/O D/O

Square D NW40H2 MasterPact circuit breaker: cat.# YA5KKR63A3SFBFXXXX, 4000 amp frame, 600 volt AC, three pole, 4000 amp rated. 85kA @ 480V, Micrologic 5.0 P trip unit with LSI functions, Modbus, spring charging motor- 100-130 Volt AC/DC, shunt trip- 24-30 Volt AC/DC, closing coil - 100-130 VAC/DC, electrically operated (E/O), draw-out (D/O), used tested with report.** Small Chip in Bottom RT. Corner**.
SKU: MCCB1506
$21,600.00

Square D MasterPact NW40H2 Circuit Breaker 4000 Amp 600 VAC M/O D/O

Square D NW40H2 MasterPact circuit breaker; cat # YA5KJR44A9SXXXXXXA, 4000 amp, 600 volt AC, three pole. With Micrologic 6.0 amp trip unit, LSIG functions, ground fault, 3200 amp rating plug, key interlock, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1930
Contact us for pricing:

Square D MasterPact NW40H2 Circuit Breaker 4000 Amp 600 VAC M/O D/O

Square D NW40H2 MasterPact circuit breaker; cat# YA5KJR44A9SXFXXXXA, 4000 amp, 600 volt AC, three pole. With Micrologic 6.0 amp trip unit, LSIG functions, ground fault, 3200 amp rating plug, key interlock, shunt trip: 100-130 volt AC/DC. manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1931
Contact us for pricing:

Square D MasterPact NW40H2 Circuit Breaker 4000 Amp 600 Volt AC

Square D MasterPact NW40H2 low- voltage power circuit breaker; 4000 amp cat# YA5KKR64A3GGFFWXCX, 600 volt AC, 3 pole. With micrologic 6.0 P trip unit, LSIG functions, ground fault. spring charging motor: 100-130 volt DC, shunt trip: 100-130 volt AC/DC, closing coil: 100-130 volt AC/DC. Used tested with report.
SKU: MCCB2083
Contact us for pricing:

Square D MasterPact NW40H2 Circuit Breaker 4000 Amp 600 Volt AC D/O

Square D MasterPact NW40H2 Circuit Breaker; cat# YA5KKR64A3GGFFWXCX, 4000 amp, 600 volt AC, draw-out (D/O). With Micrologic 6.0 P trip unit, LSIG functions, ground fault, 4000 amp rating plug, spring charging motor: 100-130 volts DC, shunt trip: 100-130 volt AC/DC, closing coil: 100-130 volts AC/DC . Used tested with report.
SKU: MCCB2082
Contact us for pricing:

Square D MasterPact NW40L Circuit Breaker 4000 Amp 600 Volt AC M/O D/O

Square D MasterPact NW40L Circuit Breaker; Cat# YL7KKR33A9DPBBWXCA, 4000 amp, 600 volt AC, 3 pole. With micrologic 5.0 trip unit, LSI functions, spring charging motor: 440-480 volt AC, shunt trip: 24-30 volt AC/DC, closing coil: 24-30 volt AC/DC, manually operated (M/O), draw-out (D/O). Used tested with report.
SKU: MCCB2122
Contact us for pricing:

Square D MasterPact NW50H3 Circuit Breaker 5000 Amp 600 VAC E/O D/O

Square D NW50H3 MasterPact circuit breaker; cat# YA6LLR64A3SFFFXHXA, 5000 amp, 600 volt AC, three pole. With Micrologic 6.0P trip unit, LSIG functions, ground fault, spring charging motor: 100-130 volt AC, shunt trip: 100-130 volt AC/DC, closing coil: 100-130 volt AC/DC, under-voltage has been removed, key interlock, electrically operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1927
Contact us for pricing:

Square D MasterPact NW50H3 Circuit Breaker 5000 Amp 600 VAC E/O D/O

Square D NW50H3 MasterPact circuit breaker: cat# YA6LLR64A3SFFFXHXA: 5000 amp, 600 volt AC, three pole. With Micrologic 6.0P trip unit with LSIG functions, spring charging motor: 100-130 volt AC, shunt trip: 100-130 volt AC/DC, closing coil: 100-130 volt AC/DC, under-voltage has been removed, key interlock, electrically operated (E/O), draw-out (D/O). Used tested with report.
SKU: MCCB1928
Contact us for pricing:

Square D NT08L1 MasterPact Breaker 800A 600 VAC D/O M/O

Square D NT08L1 MasterPact Breaker; cat# TL8ASR44A3SXXXXXXA, 800 amp, 600 volt AC, 3 pole. With micrologic 6.0A trip unit, LSIG functions, ground fault, draw-out (D/O), manually operated (M/O), used tested with report.
SKU: MCCB1992
Contact us for pricing:

Square D NT08L1 MasterPact Breaker 800A 600 VAC D/O M/O

Square D NT08L1 MasterPact Breaker; cat# TL8ASR44A3SXXXXXXA, 800 amp, 600 volt AC, 3 pole. With micrologic 6.0A trip unit, LSIG functions, ground fault, draw-out (D/O), manually operated (M/O), used tested with report.
SKU: MCCB1993
Contact us for pricing:

Square D NT08L1 MasterPact Breaker 800A 600 VAC D/O M/O

Square D NT08L1 MasterPact Breaker; cat# TL8ASR44A3SXXXXXXA, 800 amp, 600 volt AC, 3 pole. With micrologic 6.0A trip unit, LSIG functions, ground fault, draw-out (D/O), manually operated (M/O), used tested with report.
SKU: MCCB1994
Contact us for pricing:

New, Used, and Tested Molded & Insulated Case Circuit Breakers

EMSCO has been specializing in used and refurbished molded & insulated case circuit breakers for over 72 years.


Why Choose EMSCO for Molded Case or Insulated Case Circuit Breakers?

Want to match and replace your existing breakers? End the hassle of retrofitting your electrical system. Our extensive inventory includes a variety of Molded Case Circuit Breakers (MCCBs) and Insulated Case Circuit Breakers that are designed to seamlessly match and replace your existing breakers by brand, amp rating, voltage, frame size, or model.

New and Refurbished Products in Stock

We understand that budgets and preferences differ, so we give you the option of selecting between new and refurbished MCCBs or Insulated Case Breakers, both of which are readily available in our inventory. Choose brand-new circuit breakers for maximum performance and longevity, or look into our refurbished options, which have been rigorously tested and reconditioned to meet industry standards.

Popular Brands and Common Configurations

Our shelves are stocked with breakers from the most trusted and popular brands in the industry, ensuring you have access to dependable products. You'll find common configurations, such as different frame sizes and voltage ratings, making it simple to find the right circuit protection for your application.

Avoiding Costly Operational Downtime

Downtime can be an expensive situation. Our circuit protection products are designed for high performance and durability. You can avoid costly operational downtime due to electrical failures by using our fully-tested Molded Case or Insulated Case breakers. Our products provide reliable power and superior equipment protection.

Electrical Testing Equipment Certifying Quality and Performance

When it comes to the dependability and safety of your electrical systems, we leave nothing to chance. Our breakers are rigorously tested using current testing equipment to ensure that they meet or exceed industry standards. This ensures that your electrical installations are safe and efficient.

  • Overcurrent Protection: We verify that your breakers provide accurate overcurrent protection, guaranteeing the safety of your electrical systems.
  • Trip Time: We measure the time it takes for breakers to respond to overcurrent conditions, ensuring it operates within the specified trip time.
  • Short-Circuit Withstand Capacity: Our testing evaluates the breaker’s ability to withstand short-circuit currents, preventing damage and maintaining safety.
  • Interrupting Capacity: We determine the MCCB's capability to interrupt fault currents, ensuring the utmost protection for your electrical system.

Molded Case Circuit Breaker Specifications

A sample table of ampere ratings, corresponding voltage ratings, and frame sizes for molded case circuit breakers is shown below. Please keep in mind that frame sizes and ratings can differ between manufacturers and models. For precise details on a specific MCCB, always refer to the manufacturer's specifications.

Frame Size

Ampere Rating

Voltage Rating

A

15A

120V, 240V

A

20A

120V, 240V

B

30A

120V, 240V, 480V

B50A120V, 240V, 480V
C60A240V, 480V
C100A240V, 480V
D150A240V, 480V, 600V
D200A240V, 480V, 600V
E250A240V, 480V, 600V
E300A240V, 480V, 600V
F400A240V, 480V, 600V
F600A240V, 480V, 600V
G800A240V, 480V, 600V
G1200A240V, 480V, 600V
H1600A240V, 480V, 600V

This table is a sample representation of frame sizes, ampere ratings, and voltage ratings for Molded Case Circuit Breakers, not an exhaustive list.

Molded case circuit breakers (MCCBs) and insulated case circuit breakers (ICCBs) are two distinct types of circuit protection devices used in electrical systems. Both serve the purpose of interrupting electrical currents in case of faults or overloads, but they differ in construction, application, and performance characteristics. Need Help Now? Call 800-328-1842.