Square D NW16L1 Masterpact circuit breaker: cat# WA8EER64B3DXBXXXCA, 1600 amp frame, 600 volt AC, three pole. With 1600 amp rated (UL plug B) micro logic 6.0P trip unit, LSIG functions, ground fault protection, 200kA @ 480 volt Modbus, shunt trip- 24-30 Volt AC/DC, pad lockable push button cover, manually operated (M/O), draw-out (D/O), used tested with report.
Square D NW16L1 Masterpact circuit breaker; cat.#WA8EER63B3DXBXXXCA, 1600 amp frame, 600 volt AC, three pole. With 1600 amp rated Micro logic 5.0P trip unit (UL plug B) LSI functions, 200kA @ 480 volt Mod bus, shunt trip- 24-30 VAC/DC, pad lockable push button cover, manually operated (M/O), draw-out (D/O), used tested with report.
Square D NW16L1 Masterpact circuit breaker; cat# WA8EER63B3DXBXXXCA, 1600 amp frame, 600 volt AC, three pole. With 1600 amp rated Micrologic 5.0P trip unit (UL plug B), LSI functions, 200kA @ 480 volt modbus, shunt trip- 24-30 Volt AC/DC, pad lockable push button cover, manually operated (M/O), draw-out (D/O), used tested with report. *Chipped Corners*
Square D NW20H1 Masterpact circuit breaker: cat# WA4FFR63A3CFBFXXCX, 2000 amp, 600 volt AC, three pole. With Micro logic 5.0 P trip unit, LSI functions, modbus, spring charging motor- 100-130 VAC, shunt trip- 24-30 VAC/DC, closing coil- 100-130 VAC/DC, electrically operated (E/O), draw-out (D/O), used tested with report.
Square D MasterPact NW20N Circuit Breaker; cat# WL1FF33A9SXXXXXXX, 2000 Amp, 600 volt AC, 3 pole. With micrologic 5.0A trip unit, LSI functions, electrically operated (E/O), draw-out (D/O). Used tested with report.
Square D MasterPact NW20N Circuit Breaker; cat# WL1FFR33A9SXXXXXXX, 2000 Amp, 600 volt AC, 3 pole. With micrologic 5.0A trip unit, LSI functions, electrically operated (E/O), draw-out (D/O). Used tested with report.
Square D MasterPact NW30H Circuit Breaker; cat# WL3HGG43A9SXFXXXXX 3000 amp, 600 volt AC, 3 pole. With 2500 amp rating plug, manually operated (M/O), fixed-mount (F/M). Used tested with report. **No Trip Unit
Square D NW32H1 MasterPact circuit breaker: 3200 amp, 600 volt AC, three pole. With MicroLogic 6.0A unit trip with LSIG functions, ground fault, manually operated (M/O), draw-out (D/O). Used tested with report.
Square D MasterPact NW32H1 Low-Voltage Power Circuit Breaker; cat# WA4JJR64A3CFFFXXCA, 3200 amp, 600 volt AC. With micrologic 6.0P trip unit, manually operated (M/O), roll-out (R/O). Used tested with report. *Missing 1/2 of 1 stab-on clips*
Square D MasterPact NW32H2 Circuit Breaker; cat# WASJJR64A3GXXXWXCX, 3200 amp, 600 volt AC, 3 pole. With micrologic 6.0 P trip unit, manually operated (M/O), draw-out (D/O). Used tested with a report.
Square D NW40H2 MasterPact circuit breaker: cat.# YA5KKR63A3SFBFXXXX, 4000 amp frame, 600 volt AC, three pole, 4000 amp rated. 85kA @ 480V, Micrologic 5.0 P trip unit with LSI functions, Modbus, spring charging motor- 100-130 Volt AC/DC, shunt trip- 24-30 Volt AC/DC, closing coil - 100-130 VAC/DC, electrically operated (E/O), draw-out (D/O), used tested with report.** Small Chip in Bottom RT. Corner**.
Square D NW40H2 MasterPact circuit breaker; cat# YA5KJR44A9SXFXXXXA, 4000 amp, 600 volt AC, three pole. With Micrologic 6.0 amp trip unit, LSIG functions, ground fault, 3200 amp rating plug, key interlock, shunt trip: 100-130 volt AC/DC. manually operated (M/O), draw-out (D/O), used tested with report.
Square D MasterPact NW40H2 low- voltage power circuit breaker; 4000 amp cat# YA5KKR64A3GGFFWXCX, 600 volt AC, 3 pole. With micrologic 6.0 P trip unit, LSIG functions, ground fault. spring charging motor: 100-130 volt DC, shunt trip: 100-130 volt AC/DC, closing coil: 100-130 volt AC/DC. Used tested with report.
Square D MasterPact NW40L Circuit Breaker; Cat# YL7KKR33A9DPBBWXCA, 4000 amp, 600 volt AC, 3 pole. With micrologic 5.0 trip unit, LSI functions, spring charging motor: 440-480 volt AC, shunt trip: 24-30 volt AC/DC, closing coil: 24-30 volt AC/DC, manually operated (M/O), draw-out (D/O). Used tested with report.